Semiconductor Sequencing
done
- video
- dna-sequencing
- ion-torrent
- biotechnology
My Dutch narration of a video explaining how Ion Torrent semiconductor sequencing reads DNA with a pH-sensing chip instead of light.
What it is
A two-minute explainer video with my Dutch voice-over. It shows how Ion Torrent (Ion Proton) sequencing works and why it differs from 454 sequencing: it uses no optical signals, only a semiconductor chip.
How it works
- Fragment: the DNA is broken into millions of fragments.
- Amplify: each fragment is attached to a bead and copied until the bead is fully covered. This runs automatically for millions of beads, each with a different fragment.
- Load: the beads go onto the chip, one bead per well.
- Flow: the chip is filled with a mix of DNA polymerase, primers, buffers and one type of dNTP.
- Detect: when that nucleotide is incorporated, a proton is released. This changes the pH of the solution in the well, and a sensor under the well measures the voltage change.
- Repeat: about every 15 seconds the wells are refilled with a mix containing a different nucleotide.
Reading the signal
- Match: the nucleotide binds the strand when it is complementary to the next base, a proton is released and the voltage changes.
- No match: nothing is incorporated, no proton is released, the pH stays the same and the voltage stays flat.
- Repeat bases: two identical bases in a row take up two nucleotides, so the voltage doubles. The chip registers that two identical nucleotides were incorporated.
At the end the chip sends electrical pulses to the control system and the resulting chromatogram is plotted.